Gassdetektor NO2

T100 er en 4-20mA 2-wire transmitter gassdetektor som kan måle et bredt spekter av giftige gasser og er plassert i et kompakt, solid metallhus. Den inneholder avansert SMD-elektronikk og en elektrokjemisk sensor, designet for å være vedlikeholdsfri og stabil.

Fordeler:

  • 2-wire, 4-20mA Transmitter
  • Plug-in electrochemical sensor
  • Built-in ZERO & SPAN controls
  • One person calibration
  • SMD electronic circuitry
  • Enhanced RFI and EMI resistance
  • Cost effective with high performance
  • Works with most 4-20mA controllers
  • Calibration gas ampoules available
  • Certified ATEX Eex ia IIC T4
Kategori:

Beskrivelse

Gassdetektor NO2 (Nitrogendioksid)

Monicon T100 (4-20mA) gassdetektor NO2.

Produsentens beskrivelse av gassdetektor NO2 (Nitrogen Dioxide):

The Monicon T100 is a 4-20mA 2-wire transmitter can measure a wide range of gases and is housed in a rugged, compact metallic enclosure. It incorporates advanced SMD electronics and a 3 electrode electrochemical sensor based on micro fuel cell technology, designed to be maintenance free and inherently stable.

The sensor uses the highly successful capillary diffusion barrier technology, resulting in a low temperature coefficient and a direct response to concentration, relatively unaffected by pressure. The use of electrodes based on fuel cell technology gives a high reserve of activity which results in long term stability.

Gas diffusing to the sensor electrode reacts at the surface of the electrode either by oxidation (e.g. CO, H2S, SO2, NO, H2, HCN, HCl, C2H4O, NH3) or by reduction (NO2, O3 and Cl2). Reactions are catalysed by specially developed electrode materials and are designed to be specific to the gas being sensed.

Features:

– 2-wire, 4-20mA Transmitter
– Plug-in electrochemical sensor
– Built-in ZERO & SPAN controls
– One person calibration
– SMD electronic circuitry
– Enhanced RFI and EMI resistance
– Cost effective with high performance
– Works with most 4-20mA controllers
– Calibration gas ampoules available
– Certified ATEX Eex ia IIC T4

Supply voltage Nominal 24Vdc (operates from 12Vdc to 30Vdc)
Supply current Normal: 4mA, full-scale 20mA
Ec-cell operating life in air at S.T.P. Typically 2 years
Preconditioning Requirements 1 Hour (24 hours for HCl, C2H4O, & NO)
Storage life at 0 to 20°C 6 months
Operating temperature range -20°C to +40°C
Operating pressure range Ambient ± 10%
Effect of operating pressure on accuracy Approximately 0.05% signal per mm Hg
Operating RH range 15% to 90% non-condensing
Position sensitivity None
Drift, S.T.P. continuous duty in air <2% Full Scale per month
ATEX certification II 2 G EEx ia IIC T4 (Certificate No. SIRA03ATEX2405)
Size W: 75mm, D: 58mm, H: 80mm (excluding sensor)
Weight 400g
Electromagnetic Conformance (EMC) Complies with EN50081 and EN50082
Enclosure material Durable aluminium ALSi12, magnesium content <0.4%,finished in stove enamel gray RAL7001. Stainless Steel sensor compartment. (Marine grade version available to special order)